Fluid Bed Dryer
Description
Leveraging our extensive industrial experience and robust manufacturing infrastructure, UMA CHEM PHARMA MACHINERIES designs Fluid Bed Dryers known for reliable performance and single-stage operation.
Fluid Bed Dryers are extensively used to convert solutions, suspensions, and slurries into dry powder within a short processing time, without the need for intermediate handling. The high process speed combined with controlled temperature parameters ensures optimum drying efficiency and consistent product quality.
These dryers are widely used in pharmaceutical, chemical, food, and allied process industries, where uniform drying and hygiene are critical.
Special Features
Uniform drying of material
Safe earthing system
Fan motor unit can be installed in remote areas
Application
The Fluid Bed Drying technique is ideal for rapid and uniform drying of chemical, pharmaceutical, and food products. The material may be in granular, powder, or crystalline form.
Normally, materials with an initial moisture content up to 20% are ideal for fluid bed drying; however, materials with higher moisture content can also be dried successfully with suitable process control.
Heating
Electrical heating
Steam heating
Thermic fluid heating system
Options
Customized layout
Bowl provided with vacuum conveying
Flame-proof system
HMI-based operator panel
PLC operation
Clean-in-Place (CIP) system
Available in Standard and GMP models
Batch capacity ranging from 5 kg to 500 kg
Advantages
Short drying time
Minimum material handling, more hygienic operation
PLC-based control panel for precise process control
| Capacity | UCPMFBD 30 | UCPMFBD 60 | UCPMFBD 120 | UCPMFBD 200 | UCPMFBD 300 | UCPMFBD 400 | UCPMFBD 500 | UCPMFBD 600 |
|---|---|---|---|---|---|---|---|---|
| Container Gross Volume (Ltrs) | 80 | 150 | 300 | 370 | 500 | 600 | 750 | 1000 |
| Blower Motor Power (HP) | 7.5 | 10 | 15 | 15 | 25 | 25 | 30 | 40 |
| Steam Pressure (kg/cm²) | 4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
| Steam Consumption (kg/hr) | 50 | 80 | 130 | 150 | 200 | 225 | 250 | 288 |
| Electric Heater (kW) | 20 | 36 | 60 | N.A | N.A | N.A | N.A | N.A |
| Compressed Air Pressure (bar) | 8 | 8 | 8 | 8 | 8 | 8 | 8 | 8 |
| Electrical Supply | 415 V ±10%, AC, 3 Phase, 50 Hz | 415 V ±10%, AC, 3 Phase, 50 Hz | 415 V ±10%, AC, 3 Phase, 50 Hz | 415 V ±10%, AC, 3 Phase, 50 Hz | 415 V ±10%, AC, 3 Phase, 50 Hz | 415 V ±10%, AC, 3 Phase, 50 Hz | 415 V ±10%, AC, 3 Phase, 50 Hz | 415 V ±10%, AC, 3 Phase, 50 Hz |